Found 84 Products For "30lbs 13 6kg r22 refrigerant"

Qualité 14.3LB 6.5Kg Réfrigérant Écologique AR600A Gaz pour Réfrigérateur R600a Usine

14.3LB 6.5Kg Réfrigérant Écologique AR600A Gaz pour Réfrigérateur R600a

environment Protective Refrigerant Gas R600A with High Purity Product Description R600A Physical Property Molecular weight 58.12 Boiling point, ºC -11.70 Critical Temperature, ºC 134.71 Critical pressure, Mpa 3.64 Liquid specific heat, 30ºC, [KJ/(kg·ºC)] 1.78 ODP 0 GWP 0.1 Quality index(CRAA 100-2006) Purity, % ≥99.5 Moisture, % ≤0.0010 Acidity, % ≤0.0001 Evaporated residue, % ≤0.01 Appearance Colorless and clear Odor Odorless Uses: Used in reciprocating compressor; as

Qualité 14.3LB 6.5Kg réfrigérant au propane R290 0.1 Gwp R600A réfrigérant Usine

14.3LB 6.5Kg réfrigérant au propane R290 0.1 Gwp R600A réfrigérant

Propane R290 Refrigerant Gas R600A in Cylinder Caniter Small Can Drum Product Description R600A Physical Property Molecular weight 58.12 Boiling point, ºC -11.70 Critical Temperature, ºC 134.71 Critical pressure, Mpa 3.64 Liquid specific heat, 30ºC, [KJ/(kg·ºC)] 1.78 ODP 0 GWP 0.1 Quality index(CRAA 100-2006) Purity, % ≥99.5 Moisture, % ≤0.0010 Acidity, % ≤0.0001 Evaporated residue, % ≤0.01 Appearance Colorless and clear Odor Odorless Uses: Used in reciprocating compressor;

Qualité N-butane 99,9% R600A gaz réfrigérant pour propulseur aérosol Usine

N-butane 99,9% R600A gaz réfrigérant pour propulseur aérosol

Sell N-Butane 99.9% R600A Refrigerant Gas for Aerosol Propellant Product Description R600A Physical Property Molecular weight 58.12 Boiling point, ºC -11.70 Critical Temperature, ºC 134.71 Critical pressure, Mpa 3.64 Liquid specific heat, 30ºC, [KJ/(kg·ºC)] 1.78 ODP 0 GWP 0.1 Quality index(CRAA 100-2006) Purity, % ≥99.5 Moisture, % ≤0.0010 Acidity, % ≤0.0001 Evaporated residue, % ≤0.01 Appearance Colorless and clear Odor Odorless Uses: Used in reciprocating compressor; as

Qualité 9 kg de climatiseur ménager HFC-R32 Bouteilles jetables de gaz réfrigérant Usine

9 kg de climatiseur ménager HFC-R32 Bouteilles jetables de gaz réfrigérant

Household Air Conditioner Used R32 Refrigerant Gas Product Description R32 Specifications Physical properties Items Conform M.W. 52.02 Boiling point (ºC) -53.15 Liquid density 25 ºC(g/CM3) 0.960 Vapor pressure 25 ºC(MPa) 1.702 Critical Temperature ºC 78.25 Critical Pressure,Mpa 5.808 Critical density (g/cm3) 0.430 Vaporation heat (boiling point) kj/kg 390.5 Solubility in water 25 ºC(w%) 0.440 Specific heat (liquid,25 ºC(kj/kg. ºC) 2.35 ODP 0 GWP 0.11 Technical Index Item

Qualité 99.5 9,5 kg réservoir de réfrigérant R290 au propane incolore et clair Usine

99.5 9,5 kg réservoir de réfrigérant R290 au propane incolore et clair

High Quality Propane Refrigerant R290 Tank Colors Product Description R290 Physical Property Molecular weight 44.9 Boiling point, ºC -42.2 Critical Temperature, ºC 96.67 Critical pressure, Mpa 4.25 Liquid specific heat, 30ºC, [KJ/(kg·ºC)] 1.64 ODP 0 GWP 0.01 Quality index(CRAA 100-2006) Purity, % ≥99.5 Moisture, % ≤0.0010 Acidity, % ≤0.0001 Evaporated residue, % ≤0.01 Appearance Colorless and clear Odor Odorless Packing specification: Disposable steel cylinder 25lb/9.5kg;

Qualité 990,9% Pureté 11,3 kg R507 gaz réfrigérant avec homologation CE Usine

990,9% Pureté 11,3 kg R507 gaz réfrigérant avec homologation CE

99.9% Purity 11.3kg R507 Refrigerant Gas with Ce Product Description R507 Physical Property Molecular weight 98.86 Boiling point, ºC -47.1 Critical Temperature, ºC 70.9 Critical pressure, Mpa 3.79 Liquid specific heat, 30ºC, [KJ/(kg·ºC)] 0.89 ODP 0 GWP 3900 Quality index(CRAA 100-2006) Purity, % ≥99.5 Moisture, % ≤0.0010 Acidity, % ≤0.0001 Evaporated residue, % ≤0.01 Appearance Colorless and clear Odor Odorless Packing specification: Disposable steel cylinder 25lb/11.3kg;

Qualité R134A de haute pureté réfrigérant 99,99 Air Con gaz réfrigérant Usine

R134A de haute pureté réfrigérant 99,99 Air Con gaz réfrigérant

High Purity Refrigerant Gas R134A for Air Conditioner with Disposable Cylinder Product Description Disposable Cylinder Refregerant Gas R134A Physical Property: Molecular weight 102.03 Boiling point, ºC -26.1 Critical Temperature, ºC 101.1 Critical pressure, Mpa 4.07 Liquid specific heat, 25ºC, [KJ/(kg·ºC)] 1.51 ODP 0.000 GWP 0.29 Quality index(CRAA 100-2006): Purity, % ≥99.5 Moisture, % ≤0.0010 Acidity, % ≤0.0001 Evaporated residue, % ≤0.01 Appearance Colorless and clear Odor

Qualité 11.3 kg de réfrigérant R407c à usage unique, formule Chclf2 Usine

11.3 kg de réfrigérant R407c à usage unique, formule Chclf2

11.3kg Disposable Cylinder New Mixed R407c Refrigerant Gas Product Description R407C Physical Property Molecular weight 86.2 Boiling point, ºC -43.8 Critical Temperature, ºC 86.74 Critical pressure, Mpa 4.619 Liquid specific heat, 30ºC, [KJ/(kg·ºC)] 1.51 ODP 0 GWP 1700 Quality index(CRAA 100-2006) Purity, % ≥99.5 Moisture, % ≤0.0010 Acidity, % ≤0.0001 Evaporated residue, % ≤0.01 Appearance Colorless and clear Odor Odorless Packing specification: Disposable steel cylinder 25lb

Qualité R502 Remplacement R404A Gaz réfrigérant 10,9 Kg réfrigérant automobile Usine

R502 Remplacement R404A Gaz réfrigérant 10,9 Kg réfrigérant automobile

R502 Replacement R404A Refrigerant GasProduct DescriptionR404APhysical PropertyMolecular weight97.6Boiling point, ºC-46.5Critical Temperature, ºC72.1Critical pressure, Mpa3.74Liquid specific heat, 30ºC, [KJ/(kg·ºC)]0.38ODP0GWP0.388 Quality index(CRAA 100-2006)Purity, %≥99.5Moisture, %≤0.0010Acidity, %≤0.0001Evaporated residue, %≤0.01Appearance Colorless and clear OdorOdorless Packing specification: Disposable steel cylinder 24lb/10.9kg; recoverable steel cylinder 400L, 800L,