Found 137 Products For "99 99 air con refrigerant gas"

Qualité 990,9% HFC réfrigérant R134A gaz Usine

990,9% HFC réfrigérant R134A gaz

Product Description R134a Index Unit R134a Chemical formula CH2FCF3 Molecular weight g/mol 102.0 Boiling point 101.3kpa (°C) °C -26.2 Freezing point 101.3kpa (°C) °C -96.6 Critical temperature °C 101.1 Critical pressure KPa 4066.6 Saturated liquid density (25°C) Kg/m3 1188.1 Specific heat (25°Cliquid) KJ/kg·k 1.42 Critical density g/cm3 0.512 Vaporization heat at boiling point KJ/kg 215.0 Water solubility (25°C) W% 0.15 ODP 0 GWP 0.29 Quality Specification: Index Quality

Qualité Cylindre de recyclage de gaz réfrigérant R134A avec CE Usine

Cylindre de recyclage de gaz réfrigérant R134A avec CE

Product Description R134a Index Unit R134a Chemical formula CH2FCF3 Molecular weight g/mol 102.0 Boiling point 101.3kpa (°C) °C -26.2 Freezing point 101.3kpa (°C) °C -96.6 Critical temperature °C 101.1 Critical pressure KPa 4066.6 Saturated liquid density (25°C) Kg/m3 1188.1 Specific heat (25°Cliquid) KJ/kg·k 1.42 Critical density g/cm3 0.512 Vaporization heat at boiling point KJ/kg 215.0 Water solubility (25°C) W% 0.15 ODP 0 GWP 0.29 Quality Specification: Index Quality

Qualité Réfrigérant incolore R507 99,99% Réfrigérant R 507 N° CAS 354-33-6 Usine

Réfrigérant incolore R507 99,99% Réfrigérant R 507 N° CAS 354-33-6

Refrigerant R507 Price Manufacturer in China Packaging Details: Normal Packing or Customizing 1. Disposable steel cylinder 25lb/11.3kg; 2. Recoverable steel cylinder 400L, 800L, 926L; 3. ISO-tank Product Description Item R134a R410A R404A R507 Molecular formula CH2FCF3 -- -- -- Molecular weight 102.03 72.58 97.60 98.86 Boiling point 101.3KPa (ºC) -26.10 -51.53 -46.60 -47.10 Freezing point 101.3KPa (ºC) -96.60 -- -- -- Density 30ºC (kg/m3) 1188.10 1038 1017.20 1021.90 Critical

Qualité Le gaz réfrigérant R134A remplace le gaz réfrigérant R22 Usine

Le gaz réfrigérant R134A remplace le gaz réfrigérant R22

Refrigerant Gas R134A Replace for R22 Made in China Product Description Index Quality Performance Appearance Colorless & No turbid Purity %≥ 99.9% Moisture %≤ 0.001 Acidity (as HCl)%≤ 0.0001 Evaporation residue %≤ 0.01 Chlorides(Cl-) test %≤ 0.0003 No condensable gas (V/V) %≤ 1.0 Packaging Details: Normal Packing or Customizing 1. Disposable cylinder: 13.6kg(30lbs), 22.7kg(50lbs) 2. Refillable cylinder: 400L, 800L, 926L, 1000L 3. ISO-TANK: 24MT 4. Three Slices Can: 100g--

Qualité CAS 75-28-5 HFC R410A réfrigérant 25lb 11,3kg gaz réfrigérant pour ac Usine

CAS 75-28-5 HFC R410A réfrigérant 25lb 11,3kg gaz réfrigérant pour ac

Refrigerant Gas R410A in High Purity and Best Price Product Description Index R410A Chemical formula HFC-32/HFC-125 Molecular weight 72.58 Boiling point 101.3kpa, °C -51.6 Freezing point 101.3kpa, °C -96.6 Critical temperature, °C 72.5 Critical pressure, MPa 4.95 Saturated liquid density (25°C), g/m3 1.78 Specific heat(25°Cliquid), KJ/kg·k 1.42 Critical density, g/cm3 0.512 Vaporization heat at boiling point, KJ/kg 215.0 Water Solubility(25°C), W% 0.15 ODP 0 GWP 0.2 Quality

Qualité 11.3kg R410a 25 Lb Cyl réfrigérant 25 Lb 410a gaz réfrigérant Usine

11.3kg R410a 25 Lb Cyl réfrigérant 25 Lb 410a gaz réfrigérant

Industrial Grade High Purity R410A Refrigerant Gas Product Description Index R410A Chemical formula HFC-32/HFC-125 Molecular weight 72.58 Boiling point 101.3kpa, °C -51.6 Freezing point 101.3kpa, °C -96.6 Critical temperature, °C 72.5 Critical pressure, MPa 4.95 Saturated liquid density (25°C), g/m3 1.78 Specific heat(25°Cliquid), KJ/kg·k 1.42 Critical density, g/cm3 0.512 Vaporization heat at boiling point, KJ/kg 215.0 Water Solubility(25°C), W% 0.15 ODP 0 GWP 0.2 Quality

Qualité 9 kg de climatiseur ménager HFC-R32 Bouteilles jetables de gaz réfrigérant Usine

9 kg de climatiseur ménager HFC-R32 Bouteilles jetables de gaz réfrigérant

Household Air Conditioner Used R32 Refrigerant Gas Product Description R32 Specifications Physical properties Items Conform M.W. 52.02 Boiling point (ºC) -53.15 Liquid density 25 ºC(g/CM3) 0.960 Vapor pressure 25 ºC(MPa) 1.702 Critical Temperature ºC 78.25 Critical Pressure,Mpa 5.808 Critical density (g/cm3) 0.430 Vaporation heat (boiling point) kj/kg 390.5 Solubility in water 25 ºC(w%) 0.440 Specific heat (liquid,25 ºC(kj/kg. ºC) 2.35 ODP 0 GWP 0.11 Technical Index Item

Qualité 990,9% de pureté R407c réfrigérant pour climatiseur de qualité industrielle Usine

990,9% de pureté R407c réfrigérant pour climatiseur de qualité industrielle

99.9% Purity R407c Air Conditioner Refrigerant Gas Product Description R407C Physical Property Molecular weight 86.2 Boiling point, ºC -43.8 Critical Temperature, ºC 86.74 Critical pressure, Mpa 4.619 Liquid specific heat, 30ºC, [KJ/(kg·ºC)] 1.51 ODP 0 GWP 1700 Quality index(CRAA 100-2006) Purity, % ≥99.5 Moisture, % ≤0.0010 Acidity, % ≤0.0001 Evaporated residue, % ≤0.01 Appearance Colorless and clear Odor Odorless Packing specification: Disposable steel cylinder 25lb/11.3kg;

Qualité 99.9 13,6 kg HFC134A réfrigérant recyclable pour climatiseur Usine

99.9 13,6 kg HFC134A réfrigérant recyclable pour climatiseur

Recyclable Cylinder Wholesale R134A Air Conditioner Use Refrigerant Gas Product Description R134A Index R134A Chemical formula CH2FCF3 Molecular weight 102.0 Boiling point 101.3kpa, °C -26.2 Freezing point 101.3kpa, °C -96.6 Critical temperature, °C 101.1 Critical pressure, KPa 4066.6 Saturated liquid density (25°C), Kg/m3 1188.1 Specific heat(25°Cliquid), KJ/kg·k 1.42 Critical density, g/cm3 0.512 Vaporization heat at boiling point, KJ/kg 215.0 Water Solubility(25°C), W% 0