Found 87 Products For "r134a refrigerant 30lbs"

Qualità 99.99% Tonnes Confezione del serbatoio Gas refrigerante R134A HFC134A inodore Fabbrica

99.99% Tonnes Confezione del serbatoio Gas refrigerante R134A HFC134A inodore

Chemical Formulas 99.99% Refrigerant Gas R134A Product Description R134a Index Unit R134a Chemical formula CH2FCF3 Molecular weight g/mol 102.0 Boiling point 101.3kpa (°C) °C -26.2 Freezing point 101.3kpa (°C) °C -96.6 Critical temperature °C 101.1 Critical pressure KPa 4066.6 Saturated liquid density (25°C) Kg/m3 1188.1 Specific heat (25°Cliquid) KJ/kg·k 1.42 Critical density g/cm3 0.512 Vaporization heat at boiling point KJ/kg 215.0 Water solubility (25°C) W% 0.15 ODP 0 GWP

Qualità Purezza 99,99% ISO TNAK 134a Gas per refrigerazione e condizionamento dell'aria Fabbrica

Purezza 99,99% ISO TNAK 134a Gas per refrigerazione e condizionamento dell'aria

Environmental Protection Gas Refrigerant R134A for Air Conditioning Refrigeration Product Description R134a Index Unit R134a Chemical formula CH2FCF3 Molecular weight g/mol 102.0 Boiling point 101.3kpa (°C) °C -26.2 Freezing point 101.3kpa (°C) °C -96.6 Critical temperature °C 101.1 Critical pressure KPa 4066.6 Saturated liquid density (25°C) Kg/m3 1188.1 Specific heat (25°Cliquid) KJ/kg·k 1.42 Critical density g/cm3 0.512 Vaporization heat at boiling point KJ/kg 215.0 Water

Qualità 990,99% HFC gas refrigerante R134A CH2fcf3 per la refrigerazione a temperatura ultra bassa Fabbrica

990,99% HFC gas refrigerante R134A CH2fcf3 per la refrigerazione a temperatura ultra bassa

Hfc Refrigerant Gas R134A for Ultra-Low Temperature Refrigeration Equipment Product Description Disposable Cylinder Refregerant Gas R134A Physical Property Molecular weight 102.03 Boiling point, ºC -26.1 Critical Temperature, ºC 101.1 Critical pressure, Mpa 4.07 Liquid specific heat, 25ºC, [KJ/(kg·ºC)] 1.51 ODP 0.000 GWP 0.29 Quality index(CRAA 100-2006) Purity, % ≥99.5 Moisture, % ≤0.0010 Acidity, % ≤0.0001 Evaporated residue, % ≤0.01 Appearance Colorless and clear Odor

Qualità 990,9% 13,6 kg Frigorifero R134A Bastone usa e getta per sistema di climatizzazione Fabbrica

990,9% 13,6 kg Frigorifero R134A Bastone usa e getta per sistema di climatizzazione

99.9% 13.6kg Refrigerant R134A Disposable Cylinder For AC System Product Description R134a Index Unit R134a Chemical formula CH2FCF3 Molecular weight g/mol 102.0 Boiling point 101.3kpa (°C) °C -26.2 Freezing point 101.3kpa (°C) °C -96.6 Critical temperature °C 101.1 Critical pressure KPa 4066.6 Saturated liquid density (25°C) Kg/m3 1188.1 Specific heat (25°Cliquid) KJ/kg·k 1.42 Critical density g/cm3 0.512 Vaporization heat at boiling point KJ/kg 215.0 Water solubility (25°C)

Qualità 99.9 13,6 kg HFC134A riciclabile refrigerante per condizionatori d'aria Fabbrica

99.9 13,6 kg HFC134A riciclabile refrigerante per condizionatori d'aria

Recyclable Cylinder Wholesale R134A Air Conditioner Use Refrigerant Gas Product Description R134A Index R134A Chemical formula CH2FCF3 Molecular weight 102.0 Boiling point 101.3kpa, °C -26.2 Freezing point 101.3kpa, °C -96.6 Critical temperature, °C 101.1 Critical pressure, KPa 4066.6 Saturated liquid density (25°C), Kg/m3 1188.1 Specific heat(25°Cliquid), KJ/kg·k 1.42 Critical density, g/cm3 0.512 Vaporization heat at boiling point, KJ/kg 215.0 Water Solubility(25°C), W% 0

Qualità 99.99% R134A Gas climatizzatore Gas climatizzatore R134a Inodore Fabbrica

99.99% R134A Gas climatizzatore Gas climatizzatore R134a Inodore

Wholesle All Types R134A for Refrigerant Gas Product Description R134a Index Unit R134a Chemical formula CH2FCF3 Molecular weight g/mol 102.0 Boiling point 101.3kpa (°C) °C -26.2 Freezing point 101.3kpa (°C) °C -96.6 Critical temperature °C 101.1 Critical pressure KPa 4066.6 Saturated liquid density (25°C) Kg/m3 1188.1 Specific heat (25°Cliquid) KJ/kg·k 1.42 Critical density g/cm3 0.512 Vaporization heat at boiling point KJ/kg 215.0 Water solubility (25°C) W% 0.15 ODP 0 GWP 0

Qualità 990,9% di HFC Gas refrigerante R134A Fabbrica

990,9% di HFC Gas refrigerante R134A

Product Description R134a Index Unit R134a Chemical formula CH2FCF3 Molecular weight g/mol 102.0 Boiling point 101.3kpa (°C) °C -26.2 Freezing point 101.3kpa (°C) °C -96.6 Critical temperature °C 101.1 Critical pressure KPa 4066.6 Saturated liquid density (25°C) Kg/m3 1188.1 Specific heat (25°Cliquid) KJ/kg·k 1.42 Critical density g/cm3 0.512 Vaporization heat at boiling point KJ/kg 215.0 Water solubility (25°C) W% 0.15 ODP 0 GWP 0.29 Quality Specification: Index Quality

Qualità 11.3KG 99,99% Purezza R507A cilindro usa e getta di grado industriale refrigerante Fabbrica

11.3KG 99,99% Purezza R507A cilindro usa e getta di grado industriale refrigerante

Competitive Refrigerant R507 Gas Price Product Description Item R134a R410A R404A R507 Molecular formula CH2FCF3 -- -- -- Molecular weight 102.03 72.58 97.60 98.86 Boiling point 101.3KPa (ºC) -26.10 -51.53 -46.60 -47.10 Freezing point 101.3KPa (ºC) -96.60 -- -- -- Density 30ºC (kg/m3) 1188.10 1038 1017.20 1021.90 Critical temperature (ºC) 101.10 72.50 72.10 70.90 Critical pressure ( MPa) 4.06 4.96 3.74 3.79 ODP 0 0 0 0 GWP 1300 2000 3800 3900 Purity ≥ 99.90% ≥ 99.8% ≥ 99.80%

Qualità Refrigerante a gas per auto condizionatore d'aria Fabbrica

Refrigerante a gas per auto condizionatore d'aria

Disposable Cylinder Packing or Customizing High Quality R404A Refrigerant GasProduct DescriptionR404APhysical PropertyMolecular weight97.6Boiling point, ºC-46.5Critical Temperature, ºC72.1Critical pressure, Mpa3.74Liquid specific heat, 30ºC, [KJ/(kg·ºC)]0.38ODP0GWP0.388 Quality index(CRAA 100-2006)Purity, %≥99.5Moisture, %≤0.0010Acidity, %≤0.0001Evaporated residue, %≤0.01Appearance Colorless and clear OdorOdorless Packing specification: Disposable steel cylinder 24lb/10.9kg;